Smoke alarms are an essential component of any home or workplace fire safety strategy – after all, in an emergency, their piercing beep is the first thing that alerts you to the presence of smoke. This smoke may be caused by a fire, an electrical fault, or any number of other serious risks to life and property. Fast detection is critical to fire safety, which is why it’s so important that your smoke alarms are always functioning properly.
What if your smoke alarm continues to beep even when there’s no smoke in sight?
Continuous or irregular beeping is often an indicator that a smoke alarm requires servicing, maintenance, or professional diagnostic testing. Smoke alarms use different beep patterns to communicate different issues – for example, a low battery, dust contamination, or sensor errors. Interpreting what type of beep means what is an important step in maintaining a safe and compliant home or business.
Smoke alarms in Australia and New Zealand are required to adhere to strict standards such as AS 3786: 2014 which set out performance requirements and the beep patterns that smoke alarms use to indicate malfunctions or other faults. If your smoke alarm has begun to emit one of these beep patterns, the beeping is not just a warning for you to respond – it’s telling you exactly what the issue is.
In this article, we’ll explain what steps you can take to resolve the issue and how regular maintenance can help prevent false alerts in the future. We also provide guidance on when it’s time to call in the expert fire safety technicians from Alexon. When it comes to fire safety, it’s always better to be safe than sorry.
Flat batteries are the number one culprit behind a chirping smoke alarm. Most models need a fresh set every six months to stay fire-ready. You can use a battery tester to confirm if the cells are running low, or simply swap them out as a precaution.
Before you reload, double-check the new batteries match the required voltage and have a full charge. Don’t insert duds as they won’t silence the alarm, and you’ll be right back where you started.
If you’ve changed the battery and the chirping still won’t quit, don’t panic. Some hardwired alarms with battery backup hang onto fault codes like stubborn smoke in a backdraft. You’ll need to reset the unit to clear its processor and restore normal operation.
It sounds simple, but it’s a common issue - a partially closed battery drawer will stop your smoke alarm from making a proper connection with the battery terminals. Without that contact, the unit can’t power up fully, and it’ll keep chirping to warn you.
If the alarm’s beeping and you notice the battery drawer isn’t flush, shut it firmly until you hear the click. That minor gap could be the only thing standing between you and a silent, fire-ready detector.
Check for any obstructions preventing contact with the terminals. The most common culprit? The protective pull tab of your smoke alarm battery hasn’t been fully removed.
Until the battery terminals are in direct contact, the alarm can’t draw power, and it will keep signalling that fault. Remove the tab completely to ensure a solid connection and restore the detector to full operational readiness.
Ceiling-mounted detectors collect dust like any other surface, and they’re a favourite hiding spot for spiders and insects that can interfere with sensors.
To keep your alarm operating as intended, clean the sensing chamber and surrounding area at least every six months. A quick clean can prevent nuisance beeping, false alarms, and unnecessary callouts.
If your alarm won’t stop chirping (even after a fresh battery change), there could be a fault caught in the unit’s processor. To clear it, perform a hard reset: press and hold the test/hush button for 15 to 20 seconds until the alarm sounds a full-volume test tone. This should clear any false signals in the system’s memory.
If the reset doesn’t silence it, and the unit’s over 10 years old, it’s likely reached end-of-life and no amount of troubleshooting will bring it back to code. Replace it with a compliant, photoelectric unit to stay protected and meet regulations.
If you’ve ruled out battery issues, checked for terminal obstructions, cleaned the sensing chamber, and confirmed the device isn’t exposed to environmental triggers like steam or heat, it’s time to check the manufacture date. You’ll find it stamped on the back of the unit. If it’s older than eight years, consider replacing it to stay ahead of failure.
This isn’t just about stopping an annoying sound. A faulty or expired smoke alarm puts lives and property at risk. For full compliance and protection, always replace expired devices with a photoelectric alarm that meets Australian fire safety standards. And remember, routine smoke alarm testing and maintenance are critical to keeping your first line of fire defence in working order.
Regular testing is the simplest and most effective way to ensure your smoke alarms are operational. Press and hold the test button on each unit for at least 5 seconds until the alarm sounds. If the sound is weak or nonexistent, immediate action is required.
Even if your alarms are hardwired with battery backup, replacing the batteries once a year as part of your annual fire statement is essential. Relying solely on intermittent chirps to signal low battery risks missing the alert entirely.
Dust, dirt, and insect debris can impair sensor performance and lead to false alarms or failure to detect smoke. Clean the sensing chamber and external vents with a vacuum brush or compressed air at least twice a year.
For peace of mind and to ensure full compliance with Australian fire safety standards, it’s best to have your fire equipment inspected and maintained by certified fire safety professionals.
Contact Alexon today for expert fire equipment servicing, testing, and fire safety advice tailored to your property’s needs.
Complete the form to request a call
from a friendly Alexon team member.